  <Paragraph>• The properties of the standard can be changed by highlighting the standard in the tree structure 
               and selecting <Bold>Properties</Bold>.
  </Paragraph>
  <Paragraph>• Change the name of the standard in the row <Bold>Name</Bold>.
  </Paragraph>
  <Paragraph>• Change color and effect setting with the <Bold>Color and Effect</Bold> Tab.
  </Paragraph>
  
  <Paragraph Style="{DynamicResource Header}">Color Tab</Paragraph>
  
  <Paragraph>• <Bold>Difference Method</Bold>: The upper box defines the Color Difference Method. Activate 
               the desired measurement angles and input the appropriate settings. Tolerances for Pass/Fail
               indication can be set based on traffic lights.
  </Paragraph>
  <Paragraph>• <Bold>Settings</Bold>: Select the desired Statistic Options.
  </Paragraph>
  <Paragraph>• <Bold>SMC</Bold>: Statistical Measurement Control provides representative values with high 
               statistical significance. Therefore, a Standard Error needs to be defined (Std Err). The 
               minimum number of readings is defined by n standard. The maximum number of readings is 20 
               by default.
  </Paragraph>
  <Paragraph>• <Bold>General</Bold>: Select the desired illuminant and observer.
  </Paragraph>
  
  <Paragraph>• <Bold>Fluorescence Limit</Bold>: Allows activating a warning on the BYK-mac i when fluorescent 
               light excited in the visible range is detected. The limit is defined as the maximum difference between
               fluorescent compensated and non-compensated reading as percentage of the used color tolerance.
  </Paragraph>
  
  <Paragraph>• <Bold>Temp Alarm</Bold>: Allows activating a warning, if the sample temperature is out of
               the defined range.
  </Paragraph>
   
    <Paragraph Style="{DynamicResource Header}">Effect Tab</Paragraph>
  
  <Paragraph>• The <Bold>Add Scales</Bold> button allows selecting the effect scales required for tolerance setting.
               To remove scales use the Recycle bin on the right side.
  </Paragraph>
  <Paragraph>• Edit the tolerances and traffic light limits for Pass/Fail indication of the appropriate 
               effect scale.
  </Paragraph>
  
      <Paragraph Style="{DynamicResource Header}">Define Trafo Tab</Paragraph>
  
  <Paragraph>This function is of interest when the standard was measured by at least two different instrument groups
             (e.g. BYK-mac and BYK-mac i). Trafo mode is automatically activated with the latest model being selected 
             as the Trafo Reference. Trafo Mode allows converting readings of one instrument group into readings 
             of another group in order to make the instruments read alike.
  </Paragraph>
  
  <Paragraph>• Use the button <Bold>Apply</Bold> to confirm the input.
  </Paragraph>
  <Paragraph>• Use the button <Bold>Cancel</Bold> to return to the previous display. 