  <Paragraph>In the next step standard settings and tolerances are to be defined. Settings of existing
             standards can be applied.
  </Paragraph>
  <Paragraph>The top window allows selecting standards from the standard management database or any 
             linked measurement database. To change databases please use the drop down arrow in 
             the <Bold>Database</Bold> field.
  </Paragraph>
  
  <Paragraph Style="{DynamicResource Header}">Standard Management Database</Paragraph>
  
  <Paragraph>• All color families with standards as defined in Standard Management are displayed.
  </Paragraph>
  <Paragraph>• The fields in the top window can be used to filter standards out of the Standard 
               Management database by standard name.
  </Paragraph>
  
  <Paragraph Style="{DynamicResource Header}">Measurement Database</Paragraph>
  
  <Paragraph>• All standards stored in the measurement database are displayed.
  </Paragraph>
  <Paragraph>• The fields in the top window can be used to filter standards out of the measurement
               database by standard name or by inputting a time range.
  </Paragraph>
  <Paragraph>• To activate a filter criteria click on the respective item, it will be highlighted. 
               To deactivate, click it again. The symbols above each filter field enable to select 
               or deselect all items.
  </Paragraph>
  <Paragraph>• <Bold>Note</Bold>: If no item is selected, all items in the field are included in the selection.
  </Paragraph>
  
  <Paragraph>• Standards can also be selected by typing in the name or part of the name in the 
               <Bold>Search line</Bold>. Clicking on the cross at the end of the line will delete the input.
  </Paragraph>
  <Paragraph>• Select the desired standard in the result window and change the settings and tolerances if needed.
  </Paragraph>

  <Paragraph Style="{DynamicResource Header}">Color Tab</Paragraph>
  
  <Paragraph>• <Bold>Difference Method</Bold>: The upper box defines the Color Difference Method. Activate the 
               desired measurement angles and input the appropriate settings. Tolerances for Pass/Fail indication
               can be set based on traffic lights.
  </Paragraph>
  <Paragraph>• <Bold>Settings</Bold>: Select the desired Statistic Options.
  </Paragraph>
  <Paragraph>• <Bold>SMC</Bold>: Statistical Measurement Control provides representative values with high 
               statistical significance. Therefore, a Standard Error needs to be defined (Std Err). The minimum
               number of readings is defined by n standard. The maximum number of readings is 20 by default.
  </Paragraph>
  <Paragraph>• <Bold>General</Bold>: Select the desired illuminant and observer.
  </Paragraph>
  
  <Paragraph>• <Bold>Fluorescence Limit</Bold>: Allows activating a warning on the BYK-mac i when fluorescent light
               excited in the visible range is detected. The limit is defined as the maximum difference between 
               fluorescent compensated and non-compensated reading as percentage of the used color tolerance.
  </Paragraph>
  
  <Paragraph>• <Bold>Temp Alarm</Bold>: Allows activating a warning, if the sample temperature is out of the
               defined range.
  </Paragraph>
    
  <Paragraph Style="{DynamicResource Header}">Effect Tab</Paragraph>
  
  <Paragraph>• The <Bold>Add Scales</Bold> button allows selecting the effect scales required for tolerance
               setting. To remove scales use the <Bold>Recycle bin</Bold> on the right side.
  </Paragraph>
  <Paragraph>• Edit the tolerances and traffic light limits for Pass/Fail indication of the 
               appropriate effect scale.
  </Paragraph> 
  <Paragraph>• Use the button <Bold>Apply</Bold> to continue.