  <Paragraph>This window defines the  configuration and scales to be displayed on the instrument.
              </Paragraph>
  <Paragraph Style="{DynamicResource Header}">Instrument Settings</Paragraph>
  <Paragraph>• <Bold>Statistic Options</Bold>: Select the desired statistical data to be displayed.
               The readings (n) per sample are to be defined in the "Test Procedure" page.
               </Paragraph>
  <Paragraph>• <Bold>SMC</Bold> - Statistical Measurement Control provides representative values with high statistical significance.
               Therefore, an additional column appears to set a Standard Error (<Bold>Std Err</Bold>) for horizontal and vertical areas.
               The minimum number of readings is defined in the "Test Procedure"; the maximum number of readings is by default 20.
               </Paragraph>
  <Paragraph Style="{DynamicResource Header}">Advanced Settings</Paragraph>
  <Paragraph>• <Bold>Interrupt:</Bold> allows to skip checkzones or end a series before all samples are measured. 
               By deactivating the "Interrupt" function only complete series are saved.
               </Paragraph>
  <Paragraph>• <Bold>Correction:</Bold> activates recognition of defects like scratches or craters
               and calculates corrected values.
               </Paragraph>
  <Paragraph>• <Bold>Plausibility Control:</Bold> compares a corrected to an uncorrected value. 
               If the deviation is > 20%, the instrument will ask to repeat the reading.
               </Paragraph>
  <Paragraph>Additionally the unit checks the image forming qualities (IFQ) and gives a message when the readings are 
               out of linear range. Activate the function to assure that only samples with comparable IFQ are analyzed.
               </Paragraph>
  <Paragraph>• <Bold>Input ID:</Bold> an individual identification can be entered on the
               instrument for each test series, e.g. vehicle number.
               </Paragraph>
  <Paragraph>• <Bold>Input Comment:</Bold> allows to assign additional information 
               on the device for a new test series.
               </Paragraph>
  <Paragraph>• <Bold>Test series protected:</Bold> Organizer and associated measurement data can 
               not be deleted on the instrument.
               </Paragraph>
  
  <Paragraph Style="{DynamicResource Header}">Add Scales</Paragraph>
  <Paragraph>• Up to 10 scales can be displayed on the device. Select the scale from the list and click on the [+] icon. 
               To remove the scale use the Recycle bin next to it.
              </Paragraph>
  <Paragraph>• The scales will appear on the instrument as selected in the organizer.
              </Paragraph>
  <Paragraph>• For <Bold>Tolerance</Bold> setting please refer to "Standard Management" from the main menue.
              </Paragraph>
  
    <Paragraph>  </Paragraph>
  <Paragraph> Use the tab <Bold>Test Procedure</Bold> to continue.