  <Paragraph>The top window allows selecting standards from the standard management database or samples from 
             any linked measurement database. To change databases please use the drop down arrow in the 
             <Bold>Database</Bold> field.
  </Paragraph>
  
  <Paragraph Style="{DynamicResource Header}">Standard Management Database</Paragraph>
  
  <Paragraph>• All color families with standards as defined in Standard Management are displayed. Only 
               standards defined as "Master" are available for selection.
  </Paragraph>
  <Paragraph>• The fields in the top window can be used to filter standards out of the Standard 
               Management database by standard name.
  </Paragraph>
  
  <Paragraph Style="{DynamicResource Header}">Measurement Database</Paragraph>
  
  <Paragraph>• All test series stored in the measurement database are displayed in the list at the bottom.
  </Paragraph>
  <Paragraph>• To view the individual samples in a test series, click on the black arrow in front of the 
               test series. The samples have the same settings and tolerances as the standard they were 
               compared to in the test series.
  </Paragraph>
  <Paragraph>• The fields in the top window can be used to filter test series out of the measurement database 
               by time range, standard and sample name or additional parameters that were input.
  </Paragraph>
  <Paragraph>• To activate a filter criteria click on the respective item, it will be highlighted. To deactivate,
               click it again. The symbols above each filter field enable to select or deselect all items.
  </Paragraph>
  <Paragraph>• Note: If no item is selected, all items in the field are included in the selection.
  </Paragraph>
  <Paragraph>• Test series can also be selected by typing in the name or part of the name in the <Bold>Search line</Bold>.
               Clicking on the cross at the end of the line will delete the input.
  </Paragraph>
  <Paragraph>• Select the desired measurement in the result window and change the settings and tolerances if needed. 
  </Paragraph>
    
  <Paragraph Style="{DynamicResource Header}">Color Tab</Paragraph>
  
  <Paragraph>• <Bold>Difference Method</Bold>: The upper box defines the Color Difference Method. Activate the desired 
               measurement angles and input the appropriate settings. Tolerances for Pass/Fail indication can be set 
               based on traffic lights.
  </Paragraph>
  <Paragraph>• <Bold>Settings</Bold>: Select the desired Statistic Options.
  </Paragraph>
  <Paragraph>• <Bold>SMC</Bold>: Statistical Measurement Control provides representative values with high statistical 
               significance. Therefore, a Standard Error needs to be defined (Std Err). The minimum number of readings 
               is defined by n standard. The maximum number of readings is 20 by default.
  </Paragraph>
  <Paragraph>• <Bold>General</Bold>: Select the desired illuminant and observer.
  </Paragraph>
  
  <Paragraph>• <Bold>Fluorescence Limit</Bold>: Allows activating a warning on the BYK-mac i when fluorescent light excited
               in the visible range is detected. The limit is defined as the maximum difference between fluorescent
               compensated and non-compensated reading as percentage of the used color tolerance.
  </Paragraph>
  
  <Paragraph>• <Bold>Temp Alarm</Bold>: Allows activating a warning, if the sample temperature is out of the defined range.
  </Paragraph>
  
  <Paragraph Style="{DynamicResource Header}">Effect Tab</Paragraph>
  
  <Paragraph>• The <Bold>Add Scales</Bold> button allows selecting the effect scales required for tolerance setting. 
               To remove scales use the <Bold>Recycle bin</Bold> on the right side.
  </Paragraph>
  <Paragraph>• Edit the tolerances and traffic light limits for Pass/Fail indication of the appropriate effect scale.
  </Paragraph>
  <Paragraph>• Use the button <Bold>Apply</Bold> to continue. 
  </Paragraph>
  
     <Paragraph>  </Paragraph>
     
  <Paragraph>Note: The layout of the two sections at the bottom can be changed using the icons above the database
               selection field.
  </Paragraph>
  